IP = Ingress Protection
The IP class indicates how an equipment is protected against access to sensitive parts and protection against dust going inside.
Contents |
IP rating
1st digit
Protection for the equipment against ingress of solid foreign objects | Protection for persons against access to hazardous parts with | |
---|---|---|
0 | (non-protected) | (non-protected) |
1 | ≥50 mm diameter | back of hand |
2 | ≥12.5 mm diameter | finger |
3 | ≥2.5 mm diameter | tool |
4 | ≥1.0 mm diameter | wire |
5 | dust-protected | wire |
6 | dust-tight | wire |
X | not required |
2nd digit
Against ingress of water with harmful effects | |
---|---|
0 | (non-protected) |
1 | vertically dripping |
2 | dripping (15° tilted) |
3 | spraying |
4 | splashing |
5 | jetting |
6 | powerful jetting |
7 | temporary immersion |
8 | continuous immersion |
X | not required |
Additional letters (optional)
Against access to hazardous parts with | |
---|---|
A | back of hand |
B | finger |
C | tool |
D | wire |
Supplementary information specific to | |
---|---|
H | High voltage apparatus |
M | Motion during water test |
S | Stationary during water test |
W | Weather conditions |
Standards
- IEC 60529
- NEMA 250
- UL 50
- UL 508
- CSA C22.2 No. 94.