IP rating

From HwB

(Difference between revisions)
m (IP class moved to IP rating: Wrong name)
Line 1: Line 1:
 
''IP = Ingress Protection''
 
''IP = Ingress Protection''
  
The IP class indicates how an equipment is protected against access
+
The IP rating indicates how an equipment is protected against access
 
to sensitive parts and protection against dust going inside.
 
to sensitive parts and protection against dust going inside.
  
Line 15: Line 15:
 
| 0 || (non-protected)                              || (non-protected)
 
| 0 || (non-protected)                              || (non-protected)
 
|-
 
|-
| 1 || ≥50 mm diameter                           || back of hand
+
| 1 || ≥50 mm in diameter                         || back of hand
 
|-
 
|-
| 2 || ≥12.5 mm diameter                         || finger
+
| 2 || ≥12.5 mm in diameter                       || finger
 
|-
 
|-
| 3 || ≥2.5 mm diameter                           || tool
+
| 3 || ≥2.5 mm in diameter                       || tool
 
|-
 
|-
| 4 || ≥1.0 mm diameter                           || wire
+
| 4 || ≥1.0 mm in diameter                       || wire
 
|-
 
|-
 
| 5 || dust-protected                                || wire
 
| 5 || dust-protected                                || wire

Revision as of 21:40, 18 February 2007

IP = Ingress Protection

The IP rating indicates how an equipment is protected against access to sensitive parts and protection against dust going inside.

Contents

IP rating

1st digit

Protection for the equipment against ingress of solid foreign objects Protection for persons against access to hazardous parts with
0 (non-protected) (non-protected)
1 ≥50 mm in diameter back of hand
2 ≥12.5 mm in diameter finger
3 ≥2.5 mm in diameter tool
4 ≥1.0 mm in diameter wire
5 dust-protected wire
6 dust-tight wire
X not required

2nd digit

Against ingress of water with harmful effects
0 (non-protected)
1 vertically dripping
2 dripping (15° tilted)
3 spraying
4 splashing
5 jetting
6 powerful jetting
7 temporary immersion
8 continuous immersion
X not required

Additional letters (optional)

Against access to hazardous parts with
A back of hand
B finger
C tool
D wire
Supplementary information specific to
H High voltage apparatus
M Motion during water test
S Stationary during water test
W Weather conditions

Standards

  • IEC 60529
  • NEMA 250
  • UL 50
  • UL 508
  • CSA C22.2 No. 94.

Contributors

Sources