AT Keyboard/Mouse protocol
From HwB
Protocol used for:
Details:
- Protocol is bi-directional
- Clock frequency is 10-16.7 kHz
Bit | Description | Comment |
---|---|---|
1 | Start bit | Always 0 |
2-9 | 8 Data bits | LSB first |
10 | Parity bit | Odd parity |
11 | Stopp bit | Always 1 |
Contents |
Device to host
Host to device
Voltage levels
Min | Max | |
---|---|---|
Low (0) | 0.0 V | 0.7 V |
High (1) | 2.4 V | 5.25 V |